Skip to content
Access Flight Training Services
(855) 747-1200 Request training

PT6 hot start: what it is, how a hung start differs, and what to watch

In shortA PT6 hot start, in the FAA's Airplane Flying Handbook (FAA-H-8083-3C, chapter 15, p.15-12), is an engine tendency to exceed maximum starting temperature limits. A hung or false start is an engine that accelerates more slowly than normal and may stabilize too low to run without the starter, usually from low battery power or a starter not turning the engine fast enough. The handbook says temperatures may approach the maximum within 2 or 3 seconds of fuel being introduced and that the pilot should be prepared to cut off fuel. Starting limits differ by model: type certificate data sheets list 1,000°C marked 5 seconds for the King Air 200 and B200 (FAA A24CE Rev 132, p.2) and the PC-12 (EASA.A.089 Issue 11, p.6), and 1,090°C marked 2 seconds for the Caravan 208 (FAA A37CE Rev 25, p.1). The AFM or POH governs the procedure and the limit, and the engine maintenance manual decides the inspection after an over-temperature.
Twin turboprop on the ramp under a blue sky

Takeoff (5 min.): 800. Starting transient (5 sec.): 1000.

Both rows are in the engine limits table on page 2 of FAA Type Certificate Data Sheet A24CE, under maximum permissible turbine interstage temperature, and both apply to the PT6A-42 in a King Air B200. The hottest figure the table allows belongs to the start, and its time is counted in seconds.

The FAA's Airplane Flying Handbook, FAA-H-8083-3C, chapter 15, says why: after fuel is introduced, engine temperatures may approach the maximum in 2 or 3 seconds (p.15-12). A PT6 hot start is decided in that window. Your AFM or POH governs the procedure and the limits, and this article does not replace it.

The subject is the free-turbine PT6A in airplanes such as the King Air, PC-12, TBM, Meridian and Caravan. On a fixed-shaft engine such as the TPE331 the handbook gives the condition lever a different job (pp.15-3, 15-5), so that start is left out here. The transition from piston to turboprop sorts the fleet by engine.

What is a PT6 hot start, in the FAA's words?

"An engine tendency to exceed maximum starting temperature limits is termed a hot start." That is the handbook's whole definition (p.15-12). It adds that the rise may be preceded by unusually high initial fuel flow, which may be the pilot's first indication, and that serious engine damage occurs if the hot start is allowed to continue. On a PT6 the gauge is ITT, the gas temperature between the compressor turbine and the power turbines (p.15-8).

Covington Aircraft, a Pratt & Whitney Canada Designated Overhaul Facility, draws the line more narrowly in a March 2022 article. The ITT redline is the operating limit, it says, and the starting limit sits above it. A start that passes the redline without exceeding the starting limit is not classed there as a hot start, though the cause should still be found.

The shop counts from the limit and the handbook from the tendency. In the left seat, a hot start begins while the temperature is still climbing toward the limit.

Hung start vs hot start: how do the two differ?

The handbook's next paragraph defines the other failure: "A condition where the engine is accelerating more slowly than normal is termed a hung start or false start." The engine may stabilize at an rpm too low to run without the starter, usually because of low battery power or a starter not turning it fast enough.

One is a temperature event, seen on the ITT gauge. The other is an acceleration event, seen on the gas generator tachometer, labeled N1 or Ng depending on the airplane.

As we read it, the handbook gives them a shared root: when battery voltage is low, the battery's ability to turn the compressor is greatly diminished and the possibility of engine damage due to a hot start increases (p.15-10). A slow gas generator tachometer and a fast ITT needle can both come from the same weak battery.

Covington gives the mechanism: the faster the starter spools the engine up, the sooner air moves through it and carries the hot gases out.

InitialFrom $3,0503 to 5 days, about 10 flight hours
RecurrentFrom $1,8002 or 3 days, about 7 flight hours

Published tuition. Travel expenses added if we come to you. Tuition shown takes effect January 1, 2027. Courses before then are at the current rate, so ask us.

PT6 hot start procedure: what to watch, in order

The procedure is the one in your AFM or POH. The handbook supplies the order of events.

  1. Battery. Check its condition before every engine start (p.15-10). A successful start depends on the correct minimum battery voltage or a ground power unit of adequate output (p.15-12).
  2. Gas generator speed. Turbine engines have minimum rotational speeds for introducing fuel. Covington says 13 percent is typical depending on the model, that starts begun at 12 to 13 percent are much more likely to run hot, and that it is better to let the speed build to at least 17 percent first. Your AFM has your minimum.
  3. Fuel. On a PT6 the condition lever is "really just an on/off valve for delivering fuel" (p.15-6). Look at fuel flow as it comes in.
  4. Temperature and acceleration, together. This is the 2 or 3 second window. By the handbook, temperatures may approach the maximum, then fall into the normal operating range as the engine stabilizes. Its instruction here is to be prepared to cut off fuel, which on the three-lever PT6 quadrant it describes means the condition lever.
  5. Stable idle. The handbook asks for vigilant monitoring until the engine is running at a stable speed.

What causes a hot start in a turbine engine?

CauseWho names it
Low battery voltageFAA handbook (p.15-10); Covington; Pratt & Whitney's Airtime blog, 2017
Fuel introduced at a low cranking speedCovington
Unusually high initial fuel flowFAA handbook, as a possible first indication
A starter not turning the engine fast enoughFAA handbook, as a cause of a hung start
Wind from behind the airplaneSKYbrary, 2022, as a contributing factor for jet engines of any variant; we found no PT6-specific figure
A rushed or distracted startCovington, as a warning rather than a named cause

Ground power is the remedy the handbook, Covington and Tom Clements all name. Clements wrote in King Air magazine (April 2016) to use a ground power unit whenever one is conveniently available: N1 will likely stabilize at least three to four percent higher than on a battery start, with a cooler ITT peak. He recommends it in winter too, and the cold-weather side is in turboprop winter operations.

The same article describes a different over-temperature. In a generator-assisted start of a King Air's second engine at a hot, high airport, the electrical load can slow the compressor of the engine already running, and its ITT climbs. Clements says Beech specifies High Idle on that engine first, and above about 5,000 feet density altitude he sets 75 to 80 percent N1. On a twin, the engine at risk during the second start can be the one already running. Check your POH first.

Starting ITT limits on three type certificate data sheets

There is no single PT6 starting limit. These rows come from the engine limits tables of three data sheets, in the column for maximum permissible interstage or interturbine temperature, degrees C.

Airplane and engineData sheet and pageStarting row as printedTakeoff limit, same table
King Air 200 (PT6A-41) and B200 (PT6A-42)FAA A24CE Rev 132, August 21, 2026, p.2Starting transient (5 sec.): 1000750 and 800
PC-12 (PT6A-67B)EASA.A.089 Issue 11, July 7, 2025, p.6Starting Limits (5 sec.): 1000800
Caravan 208 (PT6A-114; PT6A-114A from S/N 20800277)FAA A37CE Rev 25, August 1, 2025, pp.1 and 2Starting (2 sec.): 1090805

The starting figure sits well above the takeoff figure, it carries a time in seconds, and it changes with the engine: three data sheets, two answers.

A starting limit taken from another model's data sheet or from a forum is a guess until your own AFM confirms it. A data sheet states what the type was certificated to. The limit you operate to, and how its seconds are counted, are in your AFM or POH.

What happens after a PT6A hot start?

Fuel off, as the AFM directs. Covington says to note the highest temperature reached and the time spent above the redline, because the next step depends on both.

By Covington's description, the PT6 maintenance manuals chart a hot start in three areas. Area A calls for troubleshooting, correcting the cause and a logbook entry. Area B requires a hot section inspection. Area C requires removing the engine. We have not read a PT6A maintenance manual, so treat that as the shop's summary and ask your mechanic for your engine's chart.

After a start that ran hot, your mechanic needs two numbers from you: the peak ITT and the seconds above the redline.

Covington describes damage to the compressor turbine blades and vane ring, and wrote in 2022 that the repair can cost over $100,000.

Whether you may try again is also the AFM's call. SKYbrary's entry says a second start may be attempted if the first was aborted before the limit was reached, and that maintenance action is required if the limit was exceeded.

Start habits to rehearse in initial and recurrent training

The handbook's sample training outline lists engine start procedures as a flight training item (p.15-15), and the chapter says pilot errors in engine and systems operation are common causes of aircraft damage (p.15-11).

A hot start cannot be practiced in the airplane without risking the engine, so a simulator is the place to see the malfunction itself. In the airplane you rehearse everything around it on normal starts, in initial training and again at each recurrent:

  • The battery number. The minimum voltage your AFM wants for a battery start, and when you call for ground power.
  • Your normal start. The speed at which you add fuel and the ITT peak that follows. Covington says ITT could easily be called the "money gauge", and to watch every start for anything that differs from the usual.
  • The watch order. Gas generator speed, fuel, fuel flow, ITT and acceleration, called out on every start, with a look at the windsock first.
  • The second start on a twin. Generator load, High Idle and density altitude.
  • After an abort. What your AFM says about clearing the engine and starter limits, and writing down the peak ITT and the seconds.

Access delivers initial training in your own aircraft, a King Air or a PC-12, so every start in the course is on your own battery and gauges. If the airplane is not yours yet, plan the first starts along with who flies it home after closing.

Before your next start, find two lines in the limitations section of your AFM: the starting ITT limit with its time, and the minimum gas generator speed for fuel.

Frequently asked questions

What is the difference between a hung start and a hot start in a turbine engine?

The FAA's Airplane Flying Handbook (FAA-H-8083-3C, p.15-12) defines a hot start as an engine tendency to exceed maximum starting temperature limits, and a hung or false start as an engine accelerating more slowly than normal, which may stabilize at an rpm too low to run without the starter. A PT6 hot start shows on the ITT gauge, and a hung start shows on the gas generator tachometer. The handbook ties both to low battery power.

What is the PT6 hot start procedure?

It is the one in the AFM or POH for your airplane, and it differs by model. The FAA handbook says the pilot should watch for any tendency of the temperatures to exceed limitations and be prepared to cut off fuel to the engine, and that on a PT6 the condition lever is the on/off valve for fuel. What follows the cutoff, and when another start may be attempted, is in your AFM.

How hot is too hot during a PT6A start?

It depends on the engine model. Type certificate data sheets list a starting limit of 1,000°C marked 5 seconds for the King Air 200 and B200 (FAA A24CE Rev 132, p.2) and the PC-12 (EASA.A.089 Issue 11, p.6), and 1,090°C marked 2 seconds for the Caravan 208 (FAA A37CE Rev 25, p.1). Use the limit in your own AFM or POH.

My ITT went past the redline during the start and came back down. Was that a hot start?

Covington Aircraft, a PT6A overhaul shop, wrote in March 2022 that the ITT redline is the operating limit and that the starting limit is higher, so a start that passes the redline without exceeding the starting limit is not classed as a hot start. It adds that the cause should still be found. Write down the peak temperature and the seconds above the redline and take both to your mechanic, because the engine maintenance manual decides what is required.

Can a weak battery cause a hot start?

Yes. The FAA handbook says that when battery voltage is low, the battery's ability to turn the compressor is greatly diminished and the possibility of engine damage due to a hot start increases (p.15-10). Pratt & Whitney's Airtime blog wrote in September 2017 that a battery in poor condition at start-up can cause an over-temperature that warrants an unscheduled hot section inspection. The handbook's alternative is a ground power unit of adequate output.

Sources

Access Flight Training ServicesRevised 2026-11-27

Tell us the aircraft, the airport and the date.

Paul Liberatore answers training requests himself. If you would rather talk it through first, call and ask about your airplane.